| Sight
Glass |
| |


|
Moisture
and Liquid Indicator Offers these
8 outstanding benefits.
One indicator for refrigerants
12, 22, 134a, 500 and 502.
The Moisture and Liquid Indicator
provides a true moisture indication
for either Refrigerant 12, 22, 500,
134a, or 502. The dark green indicates
dry and a bright yellow indicates
wet. The one indicator avoids the
confusion found in those makes with
2 elements. You cannot pick the wrong
element when checking the moisture
content of system.
Reliable and
Accurately Calibrated Color Change
Points.
The Moisture and Liquid Indicator
is accurately calibrated in parts
per million of moisture for each refrigerant.
All moisture indicators change color
on the basis of relative saturation
of the refrigerant. Therefore, liquid
line temperature must be considered
if an accurate calibration is to be
obtained. A color chart is part of
the label, for easy comparison.
Color changes
are easily distinguished and reversible.
The indicators color differs so widely
between WET and DRY conditions that
there is no possibility of confusion
between the two. Colors will reverse
as often as moisture concentration
in the system changes.
Large full view sight glass.
The Moisture and Liquid Indicator
has an extra large crystal clear sight
glass for viewing the refrigerant.
Bubbles indicate a shortage of refrigerant
or a restriction in the liquid line.
Indicator protected from discoloration
and dirt.
The indicator is protected by a filter
pad and screen. This prevents washing
of the indicator by the refrigerant
and protects it from system contamination
and turbulence.
Replaceable indicator element.
The color indicator paper can be changed
on the new fused glass models without
removing from the line. Replacement
is thru the bottom.
Disassembly
of the smaller sizes not required.
The extended steel fitting on solder
models in the smaller sizes make it
unnecessary to disassemble for installation
since steel conducts only one eighth
as much heat as copper.
A double duty
plastic cap
is supplied to keep the glass free
from dust, dirt, and grease. It also
permits the service engineer to use
his own discretion concerning instructions
to his customers on observing the
Moisture and Liquid Indicator.
|
|
|
 |
 |
|
|
|
 |
PDF
01 |
Application & Instruction |
|
|
|
|
|
 |
|
|
|
|
|